Supply voltage 230V.
The scope of supply includes a frame R, an intermediate frame ZR in the same colour, a
mounting plate and an adhesive film. In addition, an intermediate frame ZRF in the same
colour is supplied for installation in an existing frame R1F, R2F or R3F for flat pushbuttons.
The energy consumption indicator evaluates the information received from the wireless energy
meter transmitter module FSS12 or the wireless single-phase energy meters FWZ12 or FWZ61
and indicates alternately at a rate of 4 seconds the aggregate power consumption and the
momentary power consumption (P at the end of the display) from 15W to 65kW. In addition,
press the MOD and SEL buttons to call up consumption values in the last hours, days, months
and years.
The normal rate and off-peak status are also displayed on the FSS12 by an LED.
Display readings
The standard display appears after power is applied.
The power consumption is displayed alternating for a duration of 4 seconds. The reading,
comprising 7 digits of which there is one decimal place, ranges from 0.1 to 999999.9kWh or
the actual value of the power consumption from 15P to 65000P (active power) in watts (W).
Press the top button MOD
to page through the display options. They are indicated by a bar:
h (hours), d (days), m (months), y (years), LRN.
Press the bottom button SEL
within the display options. Each press of the button increments
the number displayed by 1 and the actual value is indicated in the display. The last full hour
then becomes the last hour but one, etc.
h01 = shows the consumption for the last hour up to h24 = 24 hours ago.
d01 = shows the consumption for the last day up to d31 = 31 days ago.
m01 = shows the consumption for the last month up to m12 = 12 months ago.
y01 = shows the consumption for the last year up to y24 = 24 years ago.
The program returns to the standard display mode automatically if MOD or SEL are not operated
for 20 seconds or if you press both buttons briefly simultaneously.
* The bottom of the housing is matt.