Output for switch functions and input to trigger control functions, e.g. optical call indication
Input distinguishes open and close
Input requires the connection of a switch with floating contact
Parameters can be adjusted without additional devices: – factory setting of switching time: 1 second / manually adjustable and via the BRE configuration tool – triggering of switching time by means of: bell buttons of any outdoor station, floor bell button / door release button at any indoor station
Connection: 2 or 3-wire technique
Max. 3 devices with 2-wire technique
Technical data
Contact type:
floating relay contact
Switch type:
make/break contact, AC 230 V, 50/60 Hz / 3 A
Input current (binary input):
2.5 mA
Input current (2-wire):
Ia-terminal: 1.5 mA without load
Input current (3-wire):
Ia-terminal: 0.4 mA IP-terminal: 1.6 mA without load IPmax: 4.4 mA
Connection:
M+, M-, a, b, P-terminal: screwless terminals max. diameter: 0.8 mm com, nc, no-terminal: screw terminals max. diameter: 1.4 mm