Switch / blinds actuator, 16/8-gang

Switch / blinds actuator, 16/8-gang

Switch / blinds actuator, 16/8-gang

Rail mounting device, 8 rail units
Switch actuator: max. 16-gang
Blind actuator: max. 8-gang
Max. 6-gang switch actuator/5-gang blind actuator in combination
with manual electronic operation and LED status indication
Only with the ETS 3.0d version or later versions the full functionality will be available.
ETS product family: Output
Product type: Binary output

More details


£560.87  excl. VAT

2316.16REGHE


Notify me when available

Intended use

  • Switching of AC 230 V electrical loads with floating contacts
  • Switching of electrically-driven Venetian blinds, shutters, awnings and similar hangings
  • Mounting on DIN rail in small distributors


 
Product characteristics

  • Outputs can be operated manually, construction site mode
  • Feedback in manual mode and in bus mode
  • Light scene function
  • Disabling of individual outputs manually or via bus


 
Characteristics switch operation

  • Operation as NO or NC contacts
  • Logic and restraint function
  • Feedback function
  • Central switching function with centralized feedback
  • Time functions: switch-on delay, switch-off delay, staircase lighting timer with pre-warning function


 
Characteristics blinds operation

  • Suitable for 230 V AC motors
  • Hanging position directly controllable
  • Slat position directly controllable
  • Feedback of movement status, blind/shutter position and slat position
  • Forced position through higher-level controller
  • Safety function: 3 independent wind alarms, rain alarm, frost alarm
  • Sun protection function


 
The total current of two adjacent outputs must not exceed 20 A.

 

  

 

 

Technical data   
Power supply   
Rated voltage: AC 230/240 V ~, 50/60 Hz 
Power loss: max. 4.5 W 
Ambient temperature: –15 ... +45 °C 
Storage/transport temperature: –25 ... +70 °C 
Outputs   
Contact type: floating relay contacts (μ contact) 
Switch type: make contact 
Switching voltage: AC 250 V ~ 
Switching current AC1 (cos ϕ > 0.8): 16 A 
Fluorescent lamps: 16 AX 
Current carrying capacity   
  Neighbouring outputs: Σ 20 A 
  Device: Σ 160 A 
Loads per output   
  ohmic load: 3000 W 
  capacitive load: 16 A / 140 µF 
  Motors: 1380 VA 
  Switch-on current 200 µs: max. 800 A 
  Switch-on current 20 ms: max. 165 A 
Lamp loads   
Incandescent lamps: 3000 W 
HV halogen lamps: 2500 W 
LV halogen lamps with   
  TRONIC transformer: 1500 W 
  conventional transformer: 1200 VA 
Fluorescent lamps T5/T8   
  non-compensated: 1000 W 
  parallel compensated: 1160 W / 140 µF 
  lead-lag circuit: 2300 W / 140 µF 
Compact fluorescent lamps   
  non-compensated: 1000 W 
  parallel compensated: 1160 W / 140 µF 
Mercury vapour lamps   
  non-compensated: 1000 W 
  parallel compensated: 1160 W / 140 µF 
Connection, power supply and load   
Connection mode: screw terminals 
  single wire: 0.5 ... 4 mm2 
  stranded without ferrule: 0.5 ... 4 mm2 
  stranded with ferrule: 0.5 ... 2.5 mm2 
KNX   
Rated voltage KNX: DC 21 ... 32 V SELV 
Power consumption KNX: typical 150 mW 
Connection, KNX: terminal 
Approvals: VDE

 