Room actuator 230 V

Room actuator 230 V

Room actuator 230 V

Rail mounting device, 4 rail units
with manual electronic operation and LED status indication
Only with the ETS 3.0d version or later versions the full functionality will be available.
ETS product family: Output
Product type: Binary output

More details


£319.73  excl. VAT

RA23024REGHE


Notify me when available

Intended use

  • Switching of electrical consumers AC 230 V with floating contacts
  • Switching of electrically operated blinds, shutters, awnings and similar curtains
  • Heating outputs: electronic outputs for switching electro-thermal valve drives



Product characteristics

  • Manual output control, provisional operation
  • Feedback in manual control mode and in bus operation
  • Scene function
  • Disabling of individual outputs by hand or via the bus


 
Switching function

  • Make-contact and break-contact operation
  • Logic operation and forcing function
  • Feedback function
  • Central switching function with group feedback
  • Time functions: ON-delay, OFF-delay, staircase lighting timer with early-warning function


 
Blind/shutter function

  • Suitable for AC motors 230 V
  • Direct control of blind/shutter position
  • Direct control of slat position
  • Checkback of running state, blind/shutter position and slat position
  • Forced-control position from primary control
  • Safety function: 3 independent wind alarms, rain alarm, frost alarm
  • Sun protection function


 
Control of valve drives 230 V

  • Switching or PWM operation
  • Control of valve drives with working characteristics "normally open" or "normally closed“
  • Overload and short-circuit protection
  • Emergency operation in the event of bus failure for summer and winter
  • Protection against jamming valves
  • Forced-control position


 

 

 

 

Technical data   
KNX supply: DC 21 ... 32 V SELV 
Power consumption KNX: max. 150 mW 
Power supply mains: AC 110 ... 230 V ~, 50/60 Hz 
Power loss: max. 6 W 
Ambient temperature: –5 ... +45 °C 
Storing temperature: –25 ... +70 °C 
Mounting width: 72 mm (4 rail units) 
Connection, KNX: bus connection block 
Connection, mains and outputs: screw terminals 
  single wire: 0.5 ... 4 mm2 
  stranded without ferrule: 0.5 ... 4 mm2 
  stranded with ferrule: 0.5 ... 2.5 mm2 
Heating outputs   
Number:
Contact type: semiconductor, ε 
Switching voltage: AC 230/240 V ~ 
Switching current: 5 ... 50 mA 
Switch-on current: max. 1.5 A (2 s) 
Number of drives per output: max. 4 
Relay outputs   
Number: 4 (2 channels for operating blinds) 
Contact type: floating make contact (µ contact) 
Switching voltage: AC 230/240 V ~ 
Breaking capacity AC1: 16 A 
Breaking capacity AC3: 6 A 
Breaking capacity fluorescent lamps: 16 AX 
Switching capacities per output   
ohmic load: 3000 W 
capacitive load: 16 A / max. 140 µF 
Motors: 1380 VA 
Lamp loads:   
  Incandescent lamps: 3000 W 
  HV halogen lamps: 2500 W 
  LV halogen lamps with:   
  – TRONIC transformer: 1500 W 
  – conventional transformer: 1200 VA 
  Fluorescent lamps:   
  – non-compensated: 1000 W 
  – parallel compensated: 1160 W / max. 140 µF 
  – lead-lag circuit: 2300 W / max. 140 µF 
Approvals: VDE

 